Field Calibrators Make Everything Better

Users Are Opening Their Eyes to How Much Clearer Their Data Is - and How Much Better Their Processes Can Run - with Field Calibrators

Share Print Related RSS
Page 1 of 2 « Prev 1 | 2 View on one page

By Jim Montague, Executive Editor

Sometimes you can't see the forest for the trees, and other  times you can't see either of them because your vision has grown too blurry. But you may not notice it until you get   new eyeglasses and see the clarity you've been missing.

Similarly, to many eyeballs, most of the measurements, variables or processes in control and automation don't stay consistent or in tune for long. As a result, there's just one task more important than sensing and controlling a process application's basic parameters, and this is calibrating that application's instruments, controls and networks.

"We use field calibrators, such  as those from Martel Electronics (www.martelcorp.com) and Fluke (www.fluke.com) for all kinds of biochemical batches to monitor and verify temperature, pressure, flow and agitation. I've been using them for 40 years, and they've all gotten better during that time. We used to have separate calibrators for different functions, but now they've combined functions and become a lot more digitized. This has been helpful because there's less hysteresis with digital than with analog calibrators," says Bruce Schmeck, an instrument technician at Merck & Co. Inc. (www.merck.com) in West Point, Pa. The facility produces vaccines like Gardasil that protects against human papillomavirus (HPV), which can cause cervical cancer.

Mental Block

However, despite the advantages that field calibrators can bring to process applications, many people don't use them—some because they don't realize their advantages, and others because they don't want to take the little extra time they require.

For example, Beamex Inc. (www.beamex.com) surveyed close to 2,000 process industry professionals last year and found that 9.9% aren't calibrating their fieldbus instruments, while 13.5% in the oil, gas and petrochemical sector don't do it either. This problem may be caused partly by the 43.1% of the respondents in oil and gas who use a semi-manual calibration management system, while another 15.3% say their calibration management is still paper-based. Only 22.8% in these industries report their system is managed by specialized calibration management software. 

"Accuracy and traceability are crucial for compliance with pharmaceutical manufacturing, FDA, EPA and other standards, but I know managers who still don't grasp how important it is to keep after calibration," says Schmeck. "Everyone wants to go the cheapest route these days. They'd rather rather run at risk for a little short-term gain, instead of calibrating and making much bigger gains in the long run. They just don't know how much better it could be. When you use field calibrators, you take a process that you hope will be good and turn it into a process you know is good." 

Implementing Education

To combat this ignorance, many field calibration advocates are educating potential users about how to gain its advantages. "Field calibration is still a big paradigm shift for many people because so many processes were historically managed with the seat-of-the-pants methods," says Ned Espy, Beamex's consulting director. "And, though many technicians in the U.S. use field calibrators, the subject isn't in the curricula of a lot of engineering schools. That's why some technical, vocational and community colleges are offering courses on calibration. For instance, Coosa Valley Technical College (CVTC, www.coosavalleytech.edu) is partnering with Georgia Power  on an instrumentation technology curriculum, running their people through it, and also making it available to students just out of high school. I think about 40 suppliers, including Beamex, Emerson Process Management and Yokogawa Corp. of America, have donated equipment to Coosa Valley's program that opened last year."

Espy adds that education on field calibrators is vital because so many process instruments and their associated networks are growing more complex. "The old three wires for three separate instruments are being replaced by multivariable transmitters or flowmeters that measure flow, temperature and differential pressure, and also perform compensating flow calculations using static pressure and temperature," says Espy. "Now everything is in one instrument, but users must learn to calibrate the resulting 4-20 mA output signal as three separate indicators. Multivariable transmitters are more accurate and stable, so users may only have to test them for an hour once every couple of years. However, they still have to get out of reactive mode and get into proactive mode to make sure it gets done."

For example, Polish Oil and Gas Co.'s (PGNiG) Mazovian Gas Co. reports that it's using Beamex's MC5-IS intrinsically safe, multi-function calibrator to calibrate about 750 instruments at its Lodz plant, which produces and delivers about 4.3 billion cubic meters of natural gas to 386,000 individual clients and 350 large industrial firms in the province (Figure 1). Most of the plant's instruments measure pressure and temperature, and they're usually calibrated twice each year with the MC5-IS, which makes automated calibrations and stores all results in its memory. Calibration reports can then be printed out using Beamex's calibration software. "Customers want to pay for the exact amount of gas they've received, so our gas conversion devices must be extremely accurate," says Jacek Midera, Mazovian's instrument specialist. "Most importantly, accurate measurements and calibration ensure proper billing. Calibrating is crucial because the impact of even a small measurement error can be tremendous in terms of lost revenue."
Page 1 of 2 « Prev 1 | 2 View on one page
Share Print Reprints Permissions

What are your comments?

You cannot post comments until you have logged in. Login Here.

Comments

No one has commented on this page yet.