Voices: Feedback

Reader Feedback: Simplified Fieldbus

You Can Get More Diagnostics from Some HART 5 Devices Than from Some HART 6 or HART 7 Devices

Regarding "The Long Greenfield/articles/2014/process-control-innovations-what-future-process-plants-can-be-like/" in the August issue: "Complex, macrocycle calculations" are not required for fieldbus on DeltaV. Also, "complex fieldbus devices" are not the case with DeltaV, since with a human-centered design dashboard, Foundation has the same look and feel as a 4-20 mA/HART device. DeltaV makes fieldbus very easy, eliminating marshalling cabinets, marshalling signals virtually from software, etc. Also, it's possible to get as much diagnostics from a HART 5 device as a HART 7 device. The diagnostics aren't dependent on the HART version. In fact, you can get more diagnostics from some HART 5 devices than from some HART 6 or HART 7 devices.

Read more

More from this voice

Title

Reader Feedback: Users Need to Step Up for Standards

All We Need Is for Users to Talk to Their Instrumentation Suppliers about Building Wireless Foundation Fieldbus

11/12/2014

Reader Feedback: Lose the Manual

Our Readers Back Up Our Claim That Manuals Should Be Tossed

11/12/2014

Reader Feedback: Who Do You Trust? People or Machines?

If We Trust the Machine, Are We Not Trusting Another Human to Correctly Program the Machine to Always Take Corrective Action?

10/17/2014

Reader Feedback: Not Exactly PC-Based

PLCs and PACs Are More Robust and Include More Control Capabilities Than Those Offered Through PC-Based Control

08/18/2014

Reader Feedback: No Unified Fieldbus Standard, Ever?

Unified Standard Solely Exist Because Automation Vendors Will Always Want That Part of Their Solutions Strategy to Be Uniquely Theirs

08/18/2014

Reader Feedback: Lambda Tuning: Use It or Lose It?

Helpful If Readers Could Get Better Information Than What's Listed in The Last "Control Update" Under: "Cascade Control Recommendation Tips" in Greg McMillan's "Control Talk" Blog

05/02/2014

Reader Feedback: When Should You Calibrate Your Industrial Devices?

A Reader Says "You Should Calibrate Your Instruments With the Frequency You Established in [Your] Plan, and Never Go Longer Than a Year"

04/07/2014

Reader Feedback: No Complete Disconnect for Nuclear Plants?

You Can't Isolate a Nuclear Power Plant from Any External Data Communications

04/07/2014

Reader Feedback: Pervasive Sensing

Our Vision of Pervasive Sensors Encouraged Us to Find Innovative Ways to Not Just Power Sensors

03/05/2014

Reader Feedback: Replacing a Field Device

Is the 3 a.m., Sunday Morning Replacement the Killer App?

03/05/2014

Boiler Tuning Question

What Is the Best Method to Tune PID Values for Three-Element Drum Level Control in the Boiler?

02/14/2014

Cyber Vulnerabilities

Defending Targeted Attacks Is a Higher Bar. Focus on Prevention Alone Is Probably a Mistake

02/14/2014

An Alarming Disconnect?

The Values of Alarm Limits Are the Biggest Single Factor Governing Alarm Performance

02/14/2014

Reader Feedback: Why Is Alarm Management Such a Problem?

What's the Cost of Best Practice Alarm Management?

01/14/2014

Reader Feedback: Old Dogs Learning New Tricks

Why Are We Still Using the Same Sample Preparation Techniques That We Used 40 Years Ago?

01/14/2014

Reader Feedback: From the ControlGlobal Community

More Readers Chime in to McMillan's Emergency Shutdown of LPG Tank Farms Article

12/17/2013

Reader Feedback: Simulation Speed-Up a Good Thing

More and More, Dynamic Simulations Are Used Before Start-Up of a New Plant for Operator Training

12/17/2013

When to Trust the Operators

Not Every Abnormal Situation Can Be Foreseen, so the Question Becomes Where Do You Draw the Line?

11/13/2013

Reader Feedback: What Color Is Your Hat?

Black Hat Caters to the Hackers and Security Researchers Primarily from the IT Community, as Well as the Press

10/10/2013

Reader Feedback: Car Collisions and Process Control

A Good Challenge Is to Improve Car Process Dynamics, and Reduce the Final Control Time-Element Delay

10/09/2013