Voices: Hebert

Predicting Equipment Failures in the Process Plant

Now You Have Option of Using Your Existing Process Historian as the Front End for a Vibration Monitoring System

By Dan Hebert

 Your process plant probably has some large items of rotating machinery that could benefit from vibration monitoring, or maybe you're contemplating such an installation. In either case, you now have the option of using your existing process historian as the front end for a vibration monitoring system.

"Historically, vibration data collection rates necessary to allow detailed machinery diagnostics were too fast for plant process historians, particularly when a system encompassed dozens or hundreds of vibration channels,” says Jonathan Fox, senior software development engineer at Metrix Setpoint.

"As a result, stand-alone vibration monitoring infrastructures evolved, with their own proprietary databases, servers, display clients, security models and network connections. However, as the capabilities of the OSIsoft  PI System have improved, the ability to treat vibration waveforms as simply another type of time series data in the PI System database has become practical, and is already in use at multiple plant sites,” explains Fox.

This is a better approach for many companies. "Eastman Chemical has been an OSIsoft PI user for many years, and it's our standard process data historian,” notes Greg Bayne, control systems engineer with Eastman Chemical Co.'s  Texas operations.

"Being able to mesh machine vibration with process data easily and to have that data time/date synchronized is very beneficial. Before, data had to be exported from the proprietary vibration system and manipulated to match up with the process data, making analysis of an event very tedious and difficult. We also have a tremendous amount of in-house support for PI, all the way from the server implementation to ProcessBook expertise,” adds Bayne.

To implement this concept, Eastman Chemical purchased a vibration monitoring system from Metrix for its plant in Longview, Texas. The system has about 80 vibration measurement points on six machine trains, including two centrifugal compressors, two centrifugal refrigeration compressors and two large, vertical, double-inlet centrifugal pumps.

Vibration proximity probe transducers on the machines are used for radial shaft movement detection at each bearing location, and for thrust monitoring of shaft axial movement on each separate case on the centrifugal compressors. Accelerometers are mounted on the gearbox housing to monitor case vibration.

These devices are connected with field wiring to the control room, where they terminate at the Metrix panel, which is connected to the plant's PI servers via Ethernet. The setpoint-to-PI-adapter software application written by Metrix transfers data to the PI system.

"The biggest challenge was optimizing data collection settings in the Metrix rack and PI compression settings to find a balance between minimizing collected data, while still acquiring meaningful waveform data. We initially collected massive amounts of data, but through several iterations we've found the right balance. Of course, this was with only one operating unit online, so we'll need to go through this process as we bring future Metrix systems online, but we've learned a great deal that should help with this process,” explains Bayne.

Although the Metrix hardware uses an open protocol and can communicate with most databases, the current focus is on integration with the OSIsoft PI system. "The PI system has the broadest customer base, and its database performance meets our needs. However, we've seen interest in integration with other systems, namely proprietary condition-monitoring software developed by turbo machinery OEMs. The way that data is collected in our hardware is the same for all applications, and all that's needed for communication with external systems is an Ethernet link and a small software program to translate the data into the correct database format,” says Fox.

 

More from this voice

Title

Measuring Viscosity With Coriolis Flowmeters

It Can Be Deduced From the Excitation Coil Current

05/14/2003

Technically speaking: Will standards mesh?

Reliability, scalability and mobility are the trump cards of wireless mesh networks and should result in triumph over other wireless topologies, according to Senior Technical Editor Dan Hebert, PE.

10/24/2004

Process controllers don't do windows

Embedded operating systems dominate the process control market, but this soon could change according to Senior Technical Editor Dan Hebert in his monthly Technically Speaking column for CONTROL.

02/22/2005

Make your automation processes better

There is no lack of technologies available that can improve your automation systems. The trick is to find, evaluate, and implement them without spending an inordinate amount of time, or taking on too much risk.

05/20/2005

An alarming situation

Alarm systems of one type or another always have been part of industrial machine, robot, and skid control systems, but CONTROL Senior Technical Editor Dan Hebert, PE, notes that there's more to alarm technology than meets the eye ... or ear for that matter.

06/05/2005

Applied control theory moves out

Industry group gets automation industry support from companies that believe the partnership between industry and academia is most beneficial when theory moves out of the classroom and into the plant.

06/20/2005

Do you need a single-source middleware solution?

As integrated middleware solutions vie with best-of-breed products, Senior Tech Editor Dan Hebert wonders if there will ever be a true integrated solution that covers the entire middleware space?

07/21/2005

Use RFID to improve your automation systems

Senior Technical Editor Dan Hebert, PE, addresses RFID technology and explains how RFID systems are being lnked to process automation systems to deliver process improvements.

08/22/2005

Fiber optic sensors on the horizon

The spread of fiber optic sensor technology from the laboratory into everyday use has barely begun. It's slashed the cost of communications, and may be poised to do the same for sensing applications.

09/27/2005

Into the mesh

Senior Tech Editor Dan Hebert, PE, identifies the leading candidates for best system architecture supremacy in the wireless arena and believes software algorithms will be key for high bandwidth mesh networks.

10/19/2005

Is advanced control ready for Prime Time?

Fuzzy logic can minimize false alerts without compromising detection and notification of actual events, but there is always a tradeoff between sensitivity and increasing likelihood of false notification.

11/10/2005

Old flywheel technology finds new uses

Read how high-tech flywheels can be used in place of batteries in process plant UPSs when backup power is needed during short-term disturbances and to ride through from utility to generator power.

12/21/2005

Web mash-ups: 1+1=3

CONTROL Senior Tech Editor Dan Hebert, PE, takes an in-depth look at a new web technology that will affect how you'll use the Internet, and how this latest trend could be applied to automation.

01/16/2006

Standards bring order to chaos

Implementation of the New Sampling/Sensor Initiative (NeSSI) standards will simplify sample system design, installation and operation, fundamentally changing and improving the way we do process analysis.

02/10/2006

HMI software is disappearing

Senior Tech Editor Rich Merritt takes a look at the HMI marketplace and finds today's software packages are getting better and cheaper, but are increasingly disappearing into control system vendors' portfolios.

02/13/2006

The right tool for the job

The next horizon for portable HMI applications may be the cell phone, which is cheap, ubiquitous, and produced in larger annual quantities than any consumer electronics device in history.

03/20/2006

Data logger size matters

New requirements and regulations are constantly being foisted on you and your plant, and many of these requirements necessitate acquisition and recording of data. Compact data loggers offer a solution.

04/17/2006

PC-based control infiltrates process plants

As PC-based control becomes more widespread in process plants, often via purchased machines and process skids, companies are finding it's a short step to implementing it for control over critical processes.

05/15/2006

Who should do your next project?

Senior Tech Editor Dan Hebert, PE, takes a look at ways you can make an automation contractor selection based on project size, scope, and support requirements in this installment of Technically Speaking.

06/12/2006

Who should do your next project? Part 2

In part two of this two-part series, Senior Tech Editor Dan Hebert, PE, takes a look at how your company’s own internal capabilities and characteristics can affect automation contractor selection.

07/14/2006