Voices: Magazine Exclusives

New Technology for Analyzing HF Alkylation Processes

The ACA.HF Analyzer: The New Standard in Safety, Simplicity and Accuracy for Analyzing HF Catalyst


By Mark Clark, Alky Sulfur Operations Specialist, ConocoPhillips (Sweeny Refinery)
Steve West, Manager, Analytical and Temperature Product Development, Invensys Operations Management

1. Introduction

A vital process in petroleum refining is the synthesis of isooctane (i.e., octane) for blending in the dynamic gasoline pool. The most widely used process for octane production is HF Alkylation. In this process, HF (hydrogen fluoride; hydrofluoric acid; "acid") serves as a catalyst for the reaction of isobutane and C4 olefins to form octane or "alkylate." Prior to the development of the alkylation process, these low-molecular weight hydrocarbons were essentially waste. Alkylation turns these former waste products into the most valuable component of gasoline.

There are three main components in HF catalyst. HF is the principal component comprising about 90%. Water is usually present at around the 1% level, and the remainder is acid-soluble organics (ASO). Tight control of these constituent concentrations can save millions of dollars per year in an alkylation unit. Optimization requires monitoring the levels of all three components. In this paper, we describe our experience with a new, simple, safe and reliable system for monitoring HF catalyst composition at the ConocoPhillips refinery in Sweeny, Texas. The Invensys ACA.HF system has enabled optimization of the alkylation process for maximum profitability.

2. Control for Safety and Profitability

Safety and profitability of an alkylation unit depend on fine-tuning the controls and are maximized when the net consumption of HF is minimized. Operating at the lowest possible HF concentration, in regards to octane barrels, without risking an out-of-control phenomenon known as "acid runaway" is the optimal scenario—greatest output of octane barrels at minimum cost. If we can minimize the consumption of HF, the advantages ripple right down the supply chain. There are limitations on how much HF can be safely stored on site and it can take days to bring more in if unexpectedly needed. Accurate monitoring allows us to keep inventory low at the ConocoPhillips Sweeny refinery without risking a shortage.

Acid Runaway

The definition of a catalyst is: A substance that increases the rate of a chemical reaction without being consumed in the process. Optimal control of the HF acid regeneration operation can make a difference of millions of dollars in profit per year in octane barrels, or lost profit opportunities due to "off-color" alkylate product, non-utilized feed rates, and, worst of all, acid runaways. In acid runaway, HF’s role as a catalyst is compromised. This occurs when the HF concentration falls below a critical concentration threshold and begins participating as a reactant in undesired side reactions—reactions that consume HF and do not produce octane. Knowledge of HF and ASO concentrations are critical to avoiding this condition.

Water concentration is also critical. A small amount of water improves reaction efficiency, but too much water increases the corrosiveness of the catalyst.

In order to avoid acid runaway, an HF concentration margin must be maintained over and above the critical concentration. Obviously, uncertainty around the HF and ASO concentrations at any time requires us to maintain a greater margin and results in poorer efficiency. Accurate, real-time concentration data allows us to run at a tight yet safe margin with confidence.

HF Alkylation Process HF is not consumed; it is recycled.

3. Existing Monitoring and Control Strategies

A prerequisite for control of a process is knowledge of the key process parameters, in this case, the concentrations of HF, ASO and water in the reaction mixture. Two monitoring strategies can be found in the industry today: grab-sample extraction for laboratory analysis and online analysis.

Grab Sampling / Lab Analysis

We have nothing but the highest regard for the chemists and technicians who perform chemical analyses at our ConocoPhillips refinery laboratories. In spite of the challenges described below, the skills and training of these individuals have ensured safe, efficient operation of alkylation units for decades. Nevertheless, the disadvantages of grab sampling and lab analysis of HF cannot be overemphasized. These disadvantages arise on two fronts: safety and accuracy.

The hazardousness of HF is extreme. Not only is it severely toxic through ingestion, inhalation, or contact with skin, it is highly volatile, permeating, and corrosive. Grab samples must be taken in sealed, Monel sampling bombs by personnel wearing full protective gear and respiratory apparatus. Personnel with special training must carry out analyses in a designated, segregated laboratory area with safety showers present in the lab and along the transport route.

Analytical Challenges

HF catalyst is a reactive mixture—removing the grab sample from the process does not stop the reaction. In other words, the clock is ticking on how representative the grab sample is of the process. Removal of the sample from the bomb, and all subsequent handling must be carried out anaerobically using materials and instruments that can withstand exposure to HF. This precludes the use of ordinary laboratory glassware, most metals and plastics. No matter how efficient the analyst or accurate the results, uncertainty grows as time elapses between sampling and the return of the results. This time is at best hours, often a whole day.

Online Analysis

The composition of HF catalyst can be determined by the technique known as Fourier-Transform, Near-IR Spectroscopy (FTNIR). This powerful tool analyzes the near-IR absorption spectrum of a mixture and breaks it down into contributions from its components. Using a pre-developed chemometric model, concentration values for target components can then be derived from the IR spectrum. In the 1990s, online FTNIR instrumentation was developed for HF alkylation analysis. Moving the analysis from the lab to the process proved enormously useful. In addition to the advantages that can be enumerated by turning the above-mentioned disadvantages of grab sampling and lab analysis upside down, real-time online analysis allows us to "skate closer to the edge", in other words to narrow the control margin and realize higher efficiency.

4. The Invensys ACA.HF Solution

Although the online FTNIR brought a completely new level of control to an alkylation unit operator, the up-front and ongoing cost of the instrumentation leaves many refineries continuing to rely on lab analysis. The desire to provide the advantages of real-time, online monitoring at a lower cost led to a ConocoPhillips collaboration with Invensys on the development of the ACA.HF system for HF catalyst monitoring. In addition to lower up-front cost and a reduction in maintenance, goals in the effort were simplicity, robustness and the use of proven process analytical hardware.

Analytical Strategy

Products from the Invensys Foxboro Measurements & Instruments (M&I) brand have been used for decades in refineries and many other industries. Simple, robust analytical measurements have an established track record in the characterization of 2-component solutions. Common examples are the use of a density measurement to determine the antifreeze content of automobile engine coolant, or refractive index to measure the sugar content of wine. To characterize binary solutions, one measurement that varies uniquely with solution composition is required, because determination of one component allows the other to be inferred as the remainder to make up a total of 100%. Analogously, a ternary solution can be characterized by two measurements, so long as they vary uniquely with the concentrations of the constituents.

The HF alkylation reaction mixture is composed mainly of HF. Invensys Foxboro electrolytic conductivity sensors are a proven approach to online water determination in HF. Water dissolves in HF undergoing the following dissociation reaction: 2HF + H2O → HF2- + H3O+.

The dissolution products are ionized species, which make the solution conductive. In binary HF/water solutions, the concentration of conductive species and therefore the conductivity is determined by the water concentration (see accompanying figure).

Fortuitously, the third major constituent of HF alkylation catalyst, ASO, dissolves without the creation of ions. This means that a conductivity measurement is an uncompromised predictor of water concentration in the reaction mixture.

Conductivity is a highly developed measurement technique with a long legacy in process control. In the alkylation application, an electrodeless, non-contacting conductivity sensor was selected. In this configuration, the process passes through an unobstructed bore of inert material—a simple pipe. External to the bore, a coil called a "drive toroid" generates an oscillating magnetic field, which induces an alternating current in the process fluid. That current in turn generates an oscillating signal in a second external coil called a "sense toroid". The signal in the sense toroid is proportional to process fluid conductivity which is proportional to the water concentration.

Conductivity provides a handle on water, then a second measurement—density—is used to determine the HF and ASO concentrations. Light hydrocarbons have densities as low as 0.6 g/cc, whereas the density of pure HF is very nearly 1.0 g/cc, almost exactly the same density as water. Thus, the relative concentrations of HF and ASO affect the density of the alkylation mixture while water does not. Just as density may be used to determine the composition of a binary mixture, for example, ethanol and water as shown in the accompanying figure, it serves in the ACA.HF system to determine the concentrations of either HF or ASO.

CFT50 Digital Flowmeter and CFS10 mAss FlowtubeAs with conductivity, a proven, process-hardened Invensys Foxboro sensor accomplishes the density measurement. This sensor, known as a Coriolis sensor, measures not only density but mass flow rate, a useful diagnostic output in the ACA.HF system. A coriolis sensor is essentially a coiled tube on which a resonant vibration is induced. Mass flow and density are determined by analysis of phase shift and frequency of the tube vibration, respectively. Again as with conductivity, the fluid passes through nothing but a pipe, but in this case shaped as a coil. With two measurements, conductivity and density, two components of the catalyst are determined, and the third is simply the remainder, since:
%HF + %ASO + %Water = 100%

Second-Order Effects

Accomplishment of the HF catalyst analysis is not quite as simple as described. Two important aspects were not included for simplicity of explanation: the effect of temperature, and the second-order influence of interactions that may occur between the ASO and water.

All species in a solution affect each other directly or indirectly. In the present case, the assumption that conductivity can predict water content and that density can predict HF/ASO content in a ternary solution turned out to be extremely powerful (see figure below). However, corrections for temperature and interactions between the components were built into the ACA.HF model as refinements.

Alkylation Data Set for MOdel Development

Model

A chemometric model was developed by recording conductivity (Cond), flow (Flow), pressure (P), density (D), and temperature (T) of HF alkylation catalyst in an operating alkylation unit using the online ACA.HF system. The ACA.HF data set was time-correlated to %HF, %H2O, and %ASO from plant records over a period of four months. Using multivariate regression techniques, the data was fit to equations that predicted %H2O and %HF as functions1 of conductivity, density and temperature:

%H2O = ƒ1(Cond) +ƒ1 (Dens) + ƒ1 (Temp)
%HF = ƒ2 (Cond) +ƒ2 (Dens) + ƒ2 (Temp)

ASO was then calculated2,3:

%ASO = 100 - %HF - %H2O

%HF by ACA. HF vs FTNIR

%h2O by ACA.HF vs FTNIR

%h2O by ACA.HF vs FTNIR

The graphs to the right illustrate the tight agreement between ACA.HF and online FTNIR analyses, demonstrating that the simpler, more robust ACA.HF sensing strategy can deliver high-quality results.

Hardware

Referring to the system diagram below, the Invensys system consists of a sampling panel located in the hazardous area. All fluid-handling components, sensors and signal transmitters are located at the sampling panel. Signals are transmitted to an Invensys Eurotherm DCS and Invensys Wonderware HMI in the safe area.


¹ Proprietary functions.

² Because of refinery precedent, %ASO was determined by subtraction after calculating %H2O and %HF from the regression model. Determining %ASO by regression and %HF by subtraction is mathematically equivalent.

³ In keeping with industry precedent, results are actually reported on the basis of a 94% rather than 100% total. This assumes a 6% loading of entrained isobutane.

Advantages of ACA.HF over FTNIR

Although an FTNIR spectrometer is an extremely powerful analytical instrument, its adaptation to online operation in an alkylation process is a complex undertaking whereas conductivity and density sensors are extremely simple and reliable—essentially just lengths of pipe. Their use in HF media has long been established. ACA.HF achieves further simplification through elimination of the need to control sample temperature, and through direct installation into the fast loop. Analysis of a continuously flowing sample system obviates the need for a complex sample handling system with a frequently cycling shutoff valves that require maintenance and periodic replacement. ACA.HF outputs its own set of diagnostic information—flow rate, pressure, and temperature. The cost of an ACA.HF system is about half that of online FTNIR and in just over one year at the ConocoPhillips Sweeny refinery, there has been no required maintenance. It was commissioned in less than 2 days, requiring no special skills to install and operate that are not found in every refinery. The components are laid out on an open panel requiring no inert gas purge or HF vapor detection.

ACA.HF System DiagramAt Sweeny, we now perform one lab sample per month, down from two per week prior to the ACA.HF installation. Lab samples were previously taken every Friday and Monday—Fridays so acid levels could be established before leaving for the weekend, and Mondays so planning could be supported in the coming week. Knowing acid and ASO levels allows operation of the HF rerun in a manner that optimizes octane barrels without the risk of acid runaway. Acid runaway not only shuts down the alkylation unit, but also cuts output of the entire refinery by loss of feed to the cat crackers.

Real-time, accurate concentration data helps keep HF down and ASO up. The trouble with FTNIR at high ASO is fouling of the cuvette window, which requires the FTNIR unit to be shut down for cleaning. The ACA.HF system does not have these types of problems.

5. Summary

The advantages of online alkylation process monitoring are clear. Fine-tuning the concentrations of the key parameters—HF, ASO and water—improves profitability and safety. The Invensys ACA.HF Alkylation Solution has demonstrated at the ConocoPhillips Sweeny refinery that continuous monitoring can be achieved with lower installed cost, less maintenance, and higher reliability than ever before. At Sweeny, the ACA.HF system quickly became depended upon as the workhorse for control of the HF alkylation unit.


©2010 Invensys Systems, Inc. All rights reserved. Avantis, Eurotherm, Foxboro, InFusion, Invensys, SimSci-Esscor, Skelta, Triconex, Validation Technologies and Wonderware are trademarks of Invensys plc., its subsidiaries and affiliated companies. All other product names are the trademarks of their respective holders. rel. 08/10 PN FX-0111


More Voices

New Technology for Analyzing HF Alkylation Processes
02/09/2012
The ACA.HF Analyzer: The New Standard in Safety, Simplicity and Accuracy for Analyzing HF Catalyst

Charlie Cutler's Latest Ideas for Multivariable Controllers
01/05/2012
Process Variable Models and Adaptive Transforms

Virtually Simulating the Next Generation of Clean Energy Technologies
01/05/2012
NETL's AVESTAR Center Is Dedicated to the Safe, Reliable and Efficient Operation of Advanced Energy Plants With Carbon Capture

Solar System Boosts Oil Field Output
10/17/2011
Innovative Thermal Solar System Cuts Installation Costs, Increases Operating Efficiency and Reduces Maintenance for an Enhanced Oil Recovery Project

The Danger With Time Bombs
10/17/2011
Can Your Software Vendor Lock Up Your Software so That You Have to Buy an Upgrade? Maybe Not

Roadmap for Best Practices in Manufacturing
09/01/2011
Aberdeen Study Shows Direct Link between Improved Safety and Productivity

SEMS After Deepwater Horizon
08/25/2011
Oil and Gas Operators Have a Lot to Do Before November 15, 2011, to Meet the New SEMS Requirements

Flowmeters Phone Home
08/25/2011
Dart Oil and Gas Leverages Open Automation Software Technology to Access Real-Time Meter Data Directly From an iPhone

Risky Business--How to Optimize a Hydrocarbon Processing Plant
08/15/2011
It's All About the Trade-Offs

PcVue SCADA System Successfully Supervises Large Hadron Collider (LHC)'s Ventilation and Cooling
06/13/2011
Server Virtualization and Competitive Cost of Ownership Benefit Large-Scale Application at CERN

Cardinal Ethanol - Plant Sustainability With a Plant-Wide Optimization Control System
06/13/2011
Achieving the Highest Levels of Process Efficiencies, Yields to Successfully Competing in the Industry

Modular Automation Allows for Food Manufacturing Flexibility
06/07/2011
From the PC to the Internet Revolution, Standard, Modular Software Objects Are the Key to Easier Manufacturing Agility and Integration

Stuxnet and the Paradigm Shift in Cyber Warfare
05/19/2011
A Brief History of the Stuxnet Worm Including Its Targets, the Initial Findings, Possible Creators of the Worm and Its Effects

The Nuclear Mess
05/13/2011
Just When We Were All Getting Convinced to Let the Genie Out of the Bottle Again, We're Back Where We Were

How Do We Minimize Murphy Consequences in Automation?
04/05/2011
Murphy is Alive and Well! Minimizing Risks Is Essential to Create Solutions That Minimize Downtime

The Future of Process Management
03/29/2011
To Thrive in the Current Environment, We Need to Change the Way We Think and the Systems We Use to Manage Our Companies

Why Manufacturing Is Leading Economic Recovery
02/04/2011
The Following Opinion Piece Is by Dr. Chris Kuehl, Economic Analyst, Fabricators & Manufacturers Association, International

Neglect Level Control at Your Peril
02/01/2011
Neglect Level Control at Your Peril -- This first article in a four-part series examines reset mode tuning issues.

How to Prepare for a NERC CIP Audit (and Protect Yourself!)
01/28/2011
Do Not Exempt the Auditors or Pre-audit Assessors From Standard Safety Briefings. Not Only Is That Good Policy, the Audit Team Expects It

Cyber Threat to Control Systems: Are Companies Expecting Too Much Info?
01/25/2011
The Industry Uses the General Term "Threat Information," but During More Detailed Discussions, It Seems That The Information Companies Seek Is More Like the Traditional Military Concept of "Tactical Information"

More Water Savings through Automation
12/08/2010
Systems Integrator Helps Desert Districts Conserve Precious Resource

WirelessHART Successfully Handles Control
12/07/2010
WirelessHART Successfully Handles Control -- Tests on Stripper and Absorber Show Results Rival Those With Wired Devices

How Can the NERC CIP Standards Be Improved?
11/08/2010
NERC CIP Is a Start, but It Can Be Made Better

To Hell and Back
08/25/2010
How to Rebuild a Control Room in Five Days. Lessons in Disaster Recovery and Emergency Response

The World's Largest Economy
07/14/2010
In China, Manufacturing is Still an Honorable Profession

Operations Management: Choose An Alarm Champion
04/13/2010
You may gain impressive benefits in alarm system performance.

Brewery in a Box?
04/06/2010
Bringing the Benefits of Distributed Control to Non-Traditional Industries Can Be Both Tricky and Lucrative

Situation Critical
03/04/2010
Bad Human/System Relationships Can Quite Literally Blow Up in Everyone's Face

Optimized Plant Makes Tea in Moscow
03/04/2010
Pepsi Brews Up Batches of Lipton Tea with a State-of-the-Art Plant

Igniting Future Engineers
03/04/2010
National Programs Partner with Businesses and Trade Organizations to Encourage Students to Participate in Engineering-Related Activities

Rethink Mass Notification
02/24/2010
Properly dealing with emergencies demands integration of plant systems.

ASM Alarm Management Guidelines and ISA-18.2: How Do They Stack Up?
10/13/2009
The ISA Standard and the ASM Consortium Guidelines Both Offer Important Information About Alarm Management. Although Their Approaches Differ, They Complement One Another

Safety, Security and Complex Systems in Critical Infrastructure Protection
09/23/2009
The Global Critical Infrastructure Is Made Up of Complex Systems Which Are, In Turn, Made Up of Complex Systems Made Up of Simpler Systems

Novel Approach Enhances Control System Upgrade
08/26/2009
Measures to Mock-Up Wiring and Limit Project Scope While Incorporating Operational Improvements Provided Significant Benefits

Safety Systems for Non-Engineers
08/07/2009
What All the Hullabaloo Over Safety Instruments Systems Is About?

Optimizing Plant Operations
07/29/2009
Saudi Aramco Abqaiq Plants Partners with Integration Objects to Optimize Plant Operations

Finding Data Diamonds in Process Application Rough
07/20/2009
Entergy Uses SmartSignal's EPI*Center Software Finds Crack in Generator Turbine

Short-Circuiting Fieldbus Installation Problems
07/14/2009
Abengoa Bioenergy Learned Some Valuable Fieldbus Architecture Lessons at Its Ravenna, Neb., Greenfield Site

Web Exclusive: Fixed-Price Projects
07/14/2009
Looking at Fixed-Price Work

Automation Project Management - Org Chart Omissions
06/29/2009
Project Management Is as Much of an Art as It Is a Science. It Is the Art and Science of Getting Things Done

Working with IS and non-Signals on the Plant Floor
06/29/2009
Galvanic Isolators Can Solve Some of Your Intrinsic Safety Problems

MES: When Preparation Meets Opportunity
05/14/2009
An Innovative Implementation of MES Is How Bristol-Myers Squibb Ensured That Activities Performed at FAT Became Useful in Meeting Regulatory Requirements

Improved Fieldbus Operations with Advanced Diagnostics
05/14/2009
Eastman Needed Intrinsically Safe Fieldbus with Maximum Segment Capacity in a Harsh, Hazardous Environment. FISCO and Advanced Diagnostics Was the Way to Go

Rethink Sample System Automation
05/07/2009
Rethink Sample System Automation -- NeSSI Provides New Tools to Tackle the Challenges and Improve Performance

The Project Staff at Celulosa Arauco
04/27/2009
Environment, Safety, and Quality Goals Realized in Unusually Successful Start-Up

Control Systems Cyber Security—The Current Status of Cyber Security of Critical Infrastructures
03/23/2009
Testimony of Joseph M. Weiss Control Systems Cyber Security Expert before the Committee on Commerce, Science, and Transportation U.S. Senate

More Golly-Whiz from Google
02/27/2009
Is the iPLC to Be Found by Watching What Google Is Doing?

Wireless Wisdom: What’s Your Strategy? Where’s Your Committee?
01/12/2009
A Forum of Wireless Experts at ISA Expo 2008 Turns into a Cautionary Consensus About the Dangers of Falling in Love with Technologies and Applications That May Run Counter to Your Long-Term Wireless Strategy and Corporate Goals

The One Machine
12/22/2008
What Is the Value of a Telecommunications Network

Something Old, Something New
12/22/2008
Users of the Two Most Measured and Most Important Variables in Process Control—Temperature and Pressure—Are Benefiting from Added Intelligence, Software and Other New Technologies, but Everything Still Depends on Good Old-Fashioned Sensors and Well-Maintained Thermocouples and Resistance Temperature Detectors

Snapshots from the World of Innovation
10/10/2008
Our Resident “Futurologist” Speculates on the Future of Disk Drives, Nanobots, and High-Frequency Sounds That Cut Both Ways

The Education of the 21st-Century Process Automation
09/16/2008
The Plant of 2025 Is Going to Require a Different Kind of Operator and Engineer. Are Schools and Companies Up for the Challenge?

More Resources for Managing Your Process Analyzer Systems
08/15/2008
More Resources for Managing Your Process Analyzer Systems

Think Things Are Small Now?
08/05/2008
What the One-Molecule Sensor Might Mean for Process Control

Beach Blanket Control
07/16/2008
“PlantBerries” Won’t Control Processes Any Time Soon, but They Do Break the Link Between Many Workers and Their Control Rooms

When Is It Time to Retire Your PAT System?
07/14/2008
The Answer’s Not as Simple as It Might Appear

PAT System Reliability
07/08/2008
Site-Wide Analyzer System Reliability Requirements

Object Architectures in an Increasingly Services-Oriented World
06/12/2008
Standard Services Make the IT Underpinnings Irrelevant, Allowing End Users to Focus on the Business at Hand

Process Plant 2025
06/11/2008
One-Person-and-a-Dog Operations? Wearable HMIs? At-Home Control Rooms? Or More of the Same Ol’, Same Ol’? Here’s What May Be on the Horizon

I Am Robot and I Am Home
06/11/2008
Jeff Harrow Talks Robots, Synthetic Biology, Nano-things and Other Developments You’ll Miss If You Blink

IEC 61508 Product Approvals – Veering Off Course
06/11/2008
Upon Close Examination It Appears That the Product Approval Process of IEC 61508 (1) Has Veered Seriously Off Course, Possibly Rendering Many Safety Instrumented System (SIS) Applications Less Reliable Than Expected or Required

Saving Energy at the Swimming Pool with VFDs
05/05/2008
Variable-Frequency Drives Reduce Energy Costs and Protect Motors at South Windsor, Conn., Pool Complex

Safety Life-Cycle Planning
05/04/2008
How Planning Can Provide Cost-Effective Design and Successful Project Execution

Asset Planning vs Activity Planning
03/28/2008
Dick Morley Becomes Resigned to Air travel, Messes Up a PowerPoint Presentation and Remembers a Valuable Lesson

Which Way Wireless?
03/28/2008
ISA100.11a and WirelessHART – Your Future Wireless

Training and Keeping Your Employees
03/26/2008
How to Get and Keep the Best Techies

Field Calibration of Magnetic Flowmeters: Case Study
03/26/2008
Is Not an Easy Task to Ensure That Flowmeters Function Accurately

Capital Preservation, Businesses’ Life Blood
02/05/2008
If They Were Called ‘Instrumented Capital Preservation Systems’ Instead of Safety Instrumented Systems, Every CEO Would Insist the Company Invest in Them

The Status Quo Isnt
02/05/2008
Web Applications May Be the Next Big Thing in Computing. Are You Ready?

Semiconductor Fab Clears Air with Intelligent Motor Control
01/08/2008
Networked Recirculation Air Handlers Save Hardwiring and Programming Costs

Process Analyzer Reliability, Maintenance & Service
12/14/2007
This is the 7th and last article of the series. In this article, we shall explore how the ongoing operation and maintenance phase of the analyzer system is anticipated during project engineering and construction.

Do You Know Who Made Your Valves?
11/06/2007
Counterfeiting is a slippery business. Here’s how to minimize the risk and danger of fake process controls.

Intrinsic Safety Supports North Sea Retrofit
10/23/2007
Efficient use of intrinsic safety enables quick retrofit.

Upgrading a Wastewater SCADA System
08/30/2007
The City of Yuma installed a SCADA system to control and monitor its water and wastewater distribution system remotely. But as the city expanded, the existing SCADA system lacked the needed support, performance and diagnostic capabilities.

Caro's SP100 Report
08/30/2007
The ISA SP-100 standards committee plans to hold a demonstration of ISA100 at the Conference and Expo to be held in Houston on October 2-4. This, to stress the readiness of the networking technology and the cooperation among the potential suppliers.

Process Analyzer System Safety and Ergonomics, Part I
08/01/2007
This article is the sixth in series running in Control over the past several months.

Controlling the Whole Column
06/08/2007
In the next installment of this series, CONTROL Columnist Béla Lipták, PE, discusses the overall control strategies for optimizing the distillation column to maximize production and minimize operating costs.

A Return to Single-Loop-Integrity
03/19/2007
Control in the field is becoming mainstream once again – just as the ISA SP50 fieldbus committee predicted it would be. CONTROL's regular contributor Dave Harrold looks at the integrity of the control loop.

Getting into Enclosures
02/02/2007
Housing for control and automation devices and networks is evolving right along with the devices they contain, so it's even more important now to choose the appropriate enclosure for your application. Here's how.


Free Subscriptions

Control Digital Edition

Access the entire print issue on-line and be notified each month via e-mail when your new issue is ready for you. Subscribe today.