LIQUID LEVEL MEASUREMENT
Siemens’ Sitrans LR250 non-contacting, radar level transmitter with a new threaded polyvinylidene fluoride (PVDF) antenna for liquid and slurry measurement opens up new applications in extreme conditions such as liquid and slurry. The threaded PVDF antenna is designed for extreme conditions. It is suitable for use in food and beverage, chemical and water treatment applications.
Siemens Industry Automation
www.usa.siemens.com/level
MAINTENANCE-FREE LEVEL SENSING
LVL-B Series vibration limit switches are insensitive to material build-up, external vibration and flow noise and have no mechanical moving parts. They are FM- and CSA-certified as dust ignition-proof (DIP) for Class II and Class III, Divisions 1 and 2, Groups E-G. They are available with 500-mm (20-in.), 1000-mm (40-in.) and 1500-mm (60-in.) extension pipes.
Pepperl+Fuchs
330/486-0002
www.pepperl-fuchs.us
LEVEL MEASUREMENT, PHONE HOME
BinView web-based monitoring solutions for bins, tanks and silos offer non-contact, continuous level measurement in most types of liquids. SmartSonic ultrasonic measures the level in liquid tanks up to 60-ft tall, and SmartWave radar handle tanks up to 100-ft. Integrated with SmartBob sensors for solids in a single network, they enable users to monitor tanks over the Internet or on smart phones.
BinMaster
800/278.4241
www.binmaster.com
MODBUS FOR LEVEL TRANSMITTERS
Impulse Series continuous time domain reflectometery level transmitters now have Modbus RS-485 digital communications capability. The interface offers several modes and data formats, including ASCII, RTU, floating point, integer and others. They provide continuous level measurement of liquids to ranges up to 50 ft. (15 m). They’re fit for use in environments that are classified hazardous (Class I, Div. 1).
Ametek Drexelbrook
215-674-1234
www.drexelbrook.com
WEB-ENABLED ULTRASONIC LEVEL SENSORS
LOE web-enabled ultrasonic level sensors provide a low-cost, tailored sensing solution for monitoring liquids or solids in remote tanks. They feature power over Ethernet (POE) for easy wiring. Sensor level data is transmitted to a dedicated website that uses an open-source, MySQL database format to ensure that user data is available in any format. They provide a detection range from 4 in. to 40 ft.
Automation Products Group
888/525-7300
www.apgsensors.com
SANITARY RADAR LEVEL TRANSMITTER
Type 8138 non-contact radar level transmitter for continuous level measurement is suitable for use in small vessels that contain beverage liquids under sanitary process conditions. With a maximum 150 °C fluid temperature and depending on the flange connection, up to 16-bar pressure steam sterilization is possible. The flange connections’ design allows cleaning to hygienic standards.
Burkert
800/325-1405
www.burkert-usa.com
ALL WILL BE REVEALED
The Reveal wide-view visual indicator is available with the patented Aurora MLI, and combines a guided-wave radar level transmitter with float-based visual indication, all in a economical single chamber with our unique baffle design. The patent-pending, stainless-steel Reveal indicator, with the widest available flag in the industry, has a 140° viewing angle with up to 200 ft. viewing distance.
Orion Instruments
225/906-2343
www.orioninstruments.com
FAIL-SAFE LEVEL SENSOR
SafePoint rotary paddle level sensor has a self-validating design and detects material presence in bins and silos and continuously monitors sensor health and system power failure. This makes the SafePoint truly "fail-safe." Also available for the SafePoint is a new two-vane, stainless-steel, collapsible paddle that can be inserted from the outside of a bin or silo through a 11/4-in. coupling.
Monitor Technologies
800/766-6486
www.monitortech.com
SMART LEVEL GAUGE
The M2110L smart level gauge measures in linear and non-linear tanks and has an accuracy of 0.05% full-scale and ranges for 20 psi. It has a 4½-digit display, RS-232C, 4-20 mA communications and SPDT relay outputs with selectable dead band. Its features include backlight, damping selectable from 0.1 to 50 sec and selection of engineering units. It also displays minutes and hours time constants.
Meriam Process Technologies
216/28-1100
www.meriam.com
MULTIPARAMETER LEVEL TRANSMITTER
Levelflex FMP55 measures the overall level of a liquid and the interface between two liquids. It is the first transmitter to use two technologies in one probe. It automatically switches between them for a concise and reliable interface measurement, even in the presence of emulsion or rag layers. The level sensor has a measuring range of up to 33 ft (10 m). The transmitter offers a 4-20 mA with HART output signal.
Endress+Hauser
888-ENDRESS
www.us.endress.com
VIBRATING FORK LIQUID LEVEL SWITCH
Rosemount 2160 IEC 62591 vibrating fork liquid level switch has advanced broadcasting functions, wireless network redundancy, and 1-second update rates. It also features improved diagnostic capabilities. Typical applications for the level device include overfill protection, high- and low-level alarms, pump control (limit detection), pump protection and empty pipe detection
Emerson Process Management
800/999-9307
www.rosemount.com/level
NON-CONTACT MEASUREMENT
The SmartLine non-contact radar level meter measures distance, level, volume and mass. Based on frequency-modulated continuous wave technology, it provides a more stable measurement than pulse radar, and is well-suited for agitated process conditions It can measure the level of a wide range of liquid or granular products, including LPG and LNG.
Honeywell Process Solutions
800/343-0228
www.honeywellprocess.com
GUIDED RADAR (TDR) LEVEL METER
Optiflex 1100 guided radar level meter uses time domain reflectometry (TDR) for continuous measurement of liquids or solids. It’s a cost-effective, higher-performing replacement for traditional level meters with an intuitive, five-step quick setup procedure that gives reliable measurements within minutes. Users have a choice of three probe types up to 65 ft.
Krohne
800/FLOWING
www.krohne.com
MAGNETIC LEVEL INDICATOR
Vegamag 62 magnetic level indicator uses a magnetized float to cause a series of metal flags to rotate, indicating the position of the liquid level inside of the chamber. The corresponding bridle houses a Vegaflex guided- wave radar, which provides redundant level by transmitting a 4-20 mA signal for control. It is an ideal replacement for sight glasses, displacers and DP transmitters.
Vega Americas
800/367-5383
www.vega-americas.com
THROUGH-AIR RADAR TRANSMITTER
Magnetrol Model R82 is a loop-powered, 26-gHz, through-air, radar transmitter unaffected by turbulence, foam, mist, fog, insects or condensation. Users have the choice of the menu-driven, four-pushbutton, two-line x 16-character display, HART digital communications or PACTware for configuration via the local user interface or remotely.
Magnetrol International
800/624-8765
www.magnetrol.com
SANITARY POINT LEVEL SENSOR
The LMT point-level sensor monitors the level of liquids, viscous media and powders in food and beverage processing tanks and pipes. It can provide reliable level monitoring in storage and mixing tanks, pump monitoring to prevent run-dry conditions, and detection of media level in pipes. Its high-frequency capacitive technology allows the sensor to detect measuring points at multiple frequencies.
ifm efector inc.
800-441-8246
www.ifm.com
RADAR ON THE LEVEL
MT5000 Series of guided-wave radar transmitters is certified for use in Safety Integrity Level 2 and 3 (SIL 2/3) applications. It features an integrated graphic display and a user-friendly setup menu in a wide range of languages. A concentric waveguide directs the radar beam, alleviating divergence problems and echoes from tank walls and surrounding structures.
ABB Level Measurement
225/673-6100
www.us.abb.com

D/P PURGE CONTROLS
King-Gage D/P purge controls send a regulated, low-volume air flow to purge a length of pipe extending downward to the tank bottom. Changes in liquid depth increase or decrease the resulting internal air pressure while a differential pressure transmitter generates a 4-20 mA output proportional to the level in the tank. Accurate level measurement and repeatability to within ±0.2%.
King-Gage Systems
800/242-8871
www.king-gage.com