ALL-IN-ONE INDUSTRIAL TRANSMITTER HF8 humidity and temperature transmitters have measurement accuracy of 0.8% RH and 0.1 ˚C, and can measure humidity ranges from 0 to 100% RH and overall temperature ranges of -100 ˚C to +200 ˚C. They have 4 analog outputs and 4 alarm relays programmable to any probe input and any probe parameter. Optional digital outputs enable Ethernet and Power over Ethernet (POE) connections. Rotronic 631/427-3898 www.rotronic-usa.com
COMBUSTION EMISSIONS ANALYZER The E8500 combustion analyzer includes electrochemical sensors for O2, CO, NO, NO2, SO2, H2S; NDIR sensors for CO2, CxHy, CO; low NOx- and true NOx-capable; real-time software; wireless remote printer; internal thermoelectric chiller with condensate removal; stack gas and ambient air temperature measurements; draft and differential pressure measurements; and more. E-Instruments International 215/750-1212 www.E-Inst.com
TWO-PARAMETER TRANSMITTER The Liquiline CM442 four-wire, two-parameter transmitter for analytical sensing applications measures any combination of various parameters, including nitrate, turbidity/suspended solids, dissolved oxygen, pH/ORP, chlorine, concentration and conductivity. It is powered by 100-230 Vac 50/60 Hz, 24 Vac 50/60 Hz, or 24 Vdc; conforms to Type 4X (IP66/IP67); and is NRTL-certified. Endress+Hauser 888/ENDRESS www.us.endress.com
IN-SITU REACTION MONITORING The MB-Rx in-situ reaction monitor for research laboratories and pilot plants is a plug-and-play solution designed around analytical performance, reliability and simplicity. It has a Hastelloy ATR probe and an intuitive software interface for rapid set up of experiment templates. Permanently aligned optics and a light source with a 10-year average lifespan make it maintenance-free. ABB Analytical Measurement 800/435-7365 www.abb.com/analytical
[javascriptSnippet]
PORTABLE FLUE GAS ANALYZER The Lancom 4 analyzer is housed in a robust enclosure for reliability in harsh boiler and stack environments; easy transfer of data to a PC or memory stick via USB; support for multiple languages. Nine gas measurements include high and low CO, O2, CO2, NO2, SO2, H2S and total hydrocarbons. Measurements include combustion efficiency, excess air, oxygen normalization, loss and total NOx. Ametek Land 412/826-4444 www.ametek-land.com
PRECISION MOISTURE ANALYZERS Computrac precision moisture analysis analyzers and Jerome toxic gas detectors are used in quality control, industrial process control and environmental monitoring applications. Arizona Instrument provides complete customer service, including on-site service and calibration. In addition, AZI will test samples for feasibility, provide free trials and 24-hour technical support. Arizona Instrument 800/290-1414 www.azic.com
ACCURATE OXYGEN MEASUREMENT TDLS220 measures percent level oxygen with no interference from background gases. Tunable diode laser spectroscopy technology (TDLS) is used for critical gas measurements, including oxygen and CO concentrations for combustion control; detecting ammonia and hydrochloric acid in exhaust gas; and monitoring ppm moisture levels in aggressive gas streams. Yokogawa Corp. of America 800/888-6400 www.yokogawa.com
TWO-WIRE LIQUID TRANSMITTERS The new family of Rosemount Analytical 1066 two-wire liquid instruments are suitable for many industrial applications, including pharmaceutical and food and beverage, chemical plants, metals processing and effluent monitoring. They have the latest version of HART 7, and they are the industry’s first pH transmitters to be registered under the Fieldbus Foundation’s Interoperability Test Kit 6 (ITK6). Rosemount Analytical 800/999-9307 tinyurl.com/86mj89q
SPRING-LOADED REGULATOR RHPS series LRS(H)4 spring-loaded pressure regulator provides high accuracy for analyzer applications. It is constructed of 316L stainless steel and available in many configurations. It is designed to handle 400 bar (5,801 psig) inlet pressure (2.2mm seat), and features a low-torque, no-wear stem and removable hardened cap. Temperature performance range is from -20 °C to +80 °C (-4 °F to +176 °F). Swagelok www.swagelok.com
PURGE CONTROLLER The ePurge X is a purge controller with fully automated purge and pressurization functions. Its digital mass flow sensor self-regulates purge duration. The purge pressure range is minimum 4 bar (60 psi) and maximum 8 bar (115 psi). The operating temperature range is -20 °C to 55 °C. ePurge X is certified in hazardous areas to NEC Class 1, Division 1, Groups C, D and IEC: Zone 1, Group IIB. Applied Analytics 978/287-4222 www.a-a-inc.com
The tiny EZminiWiFi is a godsend for the plant maintenance engineers who need to make a minor modification to the HMI program or, for that matter, the PLC program. It's very easy...
Discover the benefits of American-made automation products, including stable pricing, faster delivery, and innovative features tailored to real-world applications. With superior...
Over the past 50 years, the automation technology landscape has changed dramatically, but many of the underlying industry needs remain unchanged. To learn more about what’s changed...
Watch EZAutomation's recent feature on the popular FOX Network series "Manufacturing Marvels" and discover what makes them a force to be reckoned with in industrial automation...