Digester level...an interesting problem for Sherlock Boyes...

Feb. 2, 2006
"Daniel M." wrote to the Automation List at Control.com: "...we have a waste water treatment plant, and some anaerobic digestor (height 10 m, diameter 13 m). We need to measure level AND INTERFACE in these digestor. Ex zone due to biogas presence. If someone already faced this problem, I would appreciate any comments regarding the apropriate sensor or sensors (I personally think is not possible)." Here's what I wrote back: What you need depen...
"Daniel M." wrote to the Automation List at Control.com: "...we have a waste water treatment plant, and some anaerobic digestor (height 10 m, diameter 13 m). We need to measure level AND INTERFACE in these digestor. Ex zone due to biogas presence. If someone already faced this problem, I would appreciate any comments regarding the apropriate sensor or sensors (I personally think is not possible)." Here's what I wrote back: What you need depends on what you want to measure. Is there foam in the digester? Do you need sludge blanket interface or liquid/foam interface? Foam/liquid interface can be measured by guided wave radar (also sometimes called TDR, time domain reflectrometry), and sometimes by RF admittance (Drexelbrook, Princo, E+H, and hordes of others). If you need to measure the sludge blanket in an anaerobic digester, you need to understand that nothing works really well, even differential pressure or hydrostatic level. The reason that nothing works really well is that there is not a sharp, well defined interface. There is always a "rag layer" which goofs up (that's the correct technical term, my wife's orthopedic surgeon assured me of this) the reading on radar and RF admittance. You can't use ultrasonic, even uplooking ultrasonic, for the same reason. The thing that I've seen work the best is a float that has a custom specific gravity that is calculated to be approximately (and I use the word advisedly) the specific gravity of the interface. This can get interesting if the sludge blanket is almost the same specific gravity as the liquid, say, 1.02 for the supernatant liquid and 1.1 for the sludge (this can often happen with organic sludges). Check with one of the good old time float gauge manufacturers, like Magnetrol, or Krohne. If you can pull the digester down, you can also try an armored sight gauge, with optical alarms. But this requires modifying the vessel, and your codes may make this ugly. Good luck!
Sound OFF! Blog is sponsored by ProSoft Technology, where automation connects.

Sponsored Recommendations

2024 Industry Trends | Oil & Gas

We sit down with our Industry Marketing Manager, Mark Thomas to find out what is trending in Oil & Gas in 2024. Not only that, but we discuss how Endress+Hau...

Level Measurement in Water and Waste Water Lift Stations

Condensation, build up, obstructions and silt can cause difficulties in making reliable level measurements in lift station wet wells. New trends in low cost radar units solve ...

Temperature Transmitters | The Perfect Fit for Your Measuring Point

Our video introduces you to the three most important selection criteria to help you choose the right temperature transmitter for your application. We also ta...

2024 Industry Trends | Gas & LNG

We sit down with our Industry Marketing Manager, Cesar Martinez, to find out what is trending in Gas & LNG in 2024. Not only that, but we discuss how Endress...