CG1409-Fluke

Product Rounup: Calibration Technology

Oct. 21, 2014
Fast, Accurate Measurement, Ease of Use, Automated Record-Keeping—All Are Here
MANAGE CALIBRATIONS OFFLINE
ProCalV5 software for calibration and maintenance-asset management helps users manage the calibration of metrology, process and analytical instruments. The software is 21 CFR/Part 11-compliant. Off-line users have access to the full program interface on a local mobile workstation for paperless calibration. ProCalV5 also communicates with documenting process calibrators.
Prime Technologies  
484-266-0599
www.primetechpa.com
TAKES TWO
The 721 dual-range, pressure calibrator with dual isolated pressure sensors can take simultaneous static and differential pressure measurements in a single tool for gas custody and transfer applications. It can be configured by selecting either a 16-psi or 36-psi low-pressure sensor, and then adding any of seven high-pressure ranges, including 100, 300, 500, 1,000, 1,500, 3,000 or 5,000 psi.  
Fluke
800-443-5853
www.fluke.com
SERIOUSLY ACCURATE MANOMETER
M200LS lab-standard, smart, digital manometer provides a NIST-traceable accuracy of  ±0.01% of full scale from 15 °C to 30 °C and ±0.025% of full scale from -20 °C to 15 °C and 30 °C to 50 °C. Pressure ranges from 28 in. H2O full scale to 500 psig full scale are available. M2 pressure sensors are available to measure gauge, differential, absolute or vacuum pressure.  
Meriam Process Technologies
800-817-7849
www.meriam.com
INTEGRATE A SYSTEM
Beamex’s ICS integrated calibration solution can combine calibration equipment, such as pressure, temperature and multifunction calibrators, automatic temperature blocks and automatic pressure regulators; the company’s CMX calibration management software; and documentation such as user guides or project plans. The ICS solution integrates with ERP and CMMS systems.
Beamex   
800-888-9892
www.beamex.com
HANDLES HART
With the LC-110H HART loop calibrator technicians  can adjust and configure most of the HART functions of smart transmitters in the field. The handheld can perform a full auto-calibration including PV Zero and PV Span for most HART pressure transmitters. The device features a best-in-class accuracy of ±0.01% of reading for dc current and voltage.
Martel Electronics   
855-627-8351
www.martelcalibrators.com
CALIBRATE CONTROL VALVES
ValveLink Mobile version 4.0 software comes pre-installed on intrinsically safe 475 Field Communicators, so operators can configure, calibrate, validate, diagnose and troubleshoot control valves on a Foundation fieldbus network in the field. It has an intuitive interface with touchscreen icons. Troubleshooting guides in the software help boost plant uptime.
Emerson Process Management
800-445-9723
www.emersonprocess.com

Sponsored Recommendations

2024 Industry Trends | Oil & Gas

We sit down with our Industry Marketing Manager, Mark Thomas to find out what is trending in Oil & Gas in 2024. Not only that, but we discuss how Endress+Hau...

Level Measurement in Water and Waste Water Lift Stations

Condensation, build up, obstructions and silt can cause difficulties in making reliable level measurements in lift station wet wells. New trends in low cost radar units solve ...

Temperature Transmitters | The Perfect Fit for Your Measuring Point

Our video introduces you to the three most important selection criteria to help you choose the right temperature transmitter for your application. We also ta...

2024 Industry Trends | Gas & LNG

We sit down with our Industry Marketing Manager, Cesar Martinez, to find out what is trending in Gas & LNG in 2024. Not only that, but we discuss how Endress...